19. Yoke. The yoke shall contain the stationary cutter blade and shall be attached to the reciprocating cutter housing. The yoke shall be of a material and cross-sectional area suitable to maintain cutter blade adjustment and alignment.
20. Handles. Type I shears shall be equipped with a comfortable closed double grip handle. Type II shears shall have a pistol grip handle.
21. Swivel head. Type II shears shall be provided with a swivel head having a locking device to fix the head in one of several positions. The swivel head shall contain the cutting blades.
22. Electromagnetic interference. When specified, each shear shall be electromagnetic interference free in accordance with the requirements of MIL-STD-1337 for class II B equipment. If electromagnetic interference suppression is required the manufacturer shall provide certification that the electromagnetic suppression network in the shears offered is identical to that of the shears previously tested and approved.
23. Moisture and fungus resistant treatment. When specified in the contract, electrical components of shears covered by this specification shall be moisture and fungus resistant treated with material conforming to and applied as required by MIL-T-152 and MIL-V-173 as applicable.
24. Identification plate. A corrosion resistant nameplate, permanently, and legibly marked to include the following information shall be securely attached to the shear:
a. Manufacturer’s name, model or serial number.
b. Mild steel cutting capacity.
C. Voltage.
d. Rated-load amperes.
25. Instruction book. Unless otherwise specified in the contract, the manufacturer shall furnish one copy of his standard instruction book and parts list with each shear.
26. Accessories. Each shear shall be furnished with one extra set of cutting blades and such accessories and other extra parts as normally furnished commercially.
27. Workmanship. Workmanship of the shears shall be of the quality prevailing among manufacturers normally producing shears of the type and sizes specified herein.
Contractor certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the characteristics of this Commercial Item Description, and that the product conforms to the producers own drawings, specifications, standards, and quality assurance practices. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract.